http://WWW.SOLUTIONSCOMMUNICATIONS.IN
SOLUTIONSCOMMUNICATIONS 5ac74fba6a63e101bcbb61cb False 1365 80
OK
background image not found
Found results for
'optimum signal transmission'
Bosch Fire Panel 2LOOP INR   0 INR  0
-NaN%

Bosch Fire Panel 2LOOP

The FPA‐1000‐UL Analog Addressable Fire Panel is an advanced analog control panel for small to medium facilities in commercial or public building applications. The FPA‐1000‐UL combines complete built-in Fire Alarm Control Panel (FACP) equipment such as Notification Appliance Circuits (NACs), Signaling Line Circuits (SLCs), relays, power supply, Digital Alarm Communicator Transmitter (DACT), and Ethernet connection with expandability using the option bus or plug‐in boards. The two integrated NACs can be expanded with remote addressable NAC power boosters and programmed with specific activation patterns. Features: Support for up to 508 points on two analog addressable loops Built‐in Ethernet connector for web‐browser based programming and ConettixIP Alarm-over-IP communication Carbon Monoxide Detector (gas) support meets NFPA 720 (2009) requirements for visual and audible annunciation Auto‐Learn mode for easy provisioning On‐line help and off‐line programming capability provide simple configuration and service. Trouble conditions. The built‐in keypad can be used for total system control and programming even when wearing fireman gloves. In addition, a large 4‐line by 20‐character alphanumeric LCD display shows programmed device point information. Four keys enable Drill, Reset, Silence, and Acknowledge functions. The FPA‐1000‐UL enables various programming approaches: Two different phone or IP numbers Different dialing types for PSTN (pulse only, tone and pulse, or tone only) Individual PSTN line supervision (audible and visual trouble signal in the case of a transmission path failure) Selectable options for Report Steering Groups Programmable acknowledge wait time for each IP reporting Conettix account (15 sec up to 255 sec) Test call frequency individually programmable for each account (4, 12, 24 hour, 7 and 28 day intervals, standard frequency 24 hour) Notification Appliance Circuits (NACs): Two Class A Style Z or Class B Style Y NACs provide up to 4 A of 24 V power (non-synchronized: 2.5 A per NAC; synchronized: 2.75 A NAC 1 + NAC 2 in total) to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 4, Temporal Code 3, and steady, puls- ing, and synchronized protocol output for Wheelock, Gentex, and System Sensor notification appliances. Signaling Line Circuits (SLCs): The Bosch FPA‐1000‐UL Fire Panel uses the patented DCP Digital Communication Protocol to communicate with each of the analog addressable devices located on the SLCs. This fast and reliable protocol allows the use of standard non‐twisted, non‐shielded wiring for the SLCs. The FPA‐1000‐UL supports two Class B, Style 4 or one Class A, Style 6 or 7 per SLC. Mounting Considerations: The cabinet can be either semi-flush (requires optional FPM‐1000‐SFMK Semi-flush Mounting Kit) or surface mounted. Depending on the configuration and the battery selection, the FPA‐1000‐UL can be quite heavy. When attaching the enclosure to a surface, use mounting hardware (not supplied) capable of supporting this weight, and reinforce the wall as necessary. Wiring Considerations: The length of wire allowed between the control panel and the last device on a wiring run depends on the current drawn on that wiring run. Reducing the number of devices on a wiring run allows the individual runs to be longer.

INR 0 INR 0

Availability:False

Pay mode:COD only

view details
COOPER Addressable Sensors INR   0 INR  0
-NaN%

COOPER Addressable Sensors

Photoelectric smoke sensor (opto) is suitable for most applications giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles. Opto-heat sensor will respond better to fast clean burning fires yet maintain the advantage of optical sensors when detecting smouldering fires. The thermal enhancement of this sensor allows a higher alarm threshold which provides a greater rejection of false alarms. The sensor will also give an alarm at temperatures above 135°F. Rate of rise with fixed heat sensor settings will detect a rapid increase in temperature or temperatures above 135°F and should be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions. Fixed heat sensors settings will detect temperatures above 135°F or 194°F and should be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions. For photoelectric and opto-heat operation the sensor automatically compensates for gradual increase in the scatter signal due to contamination e.g. dust build up. Features Built-in short circuit isolators Stylish low profile design 360º viewable LED design Removable detector chamber Drift compensation Benefits Plug and play - no hard addressing required ‘Clean me’ feature means sensor can be cleaned on site using the Menvier manual cleaning procedure The programmable heat sensor reduces the number of parts required in the system

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
BNC RG6 Connector INR   0 INR  0
-NaN%

BNC RG6 Connector

WBOX Model : WBC0EBNCMS. BNC PLUG BNC RG6 PLUG (Pack of 100) W Box BNC is full metal plug and used to connect a variety of different coaxial cables. It has a center pin connected to the center cable conductor and a metal tube connected to the outer cable shield. Ring outside the tube locks the cable to any female connector. Full metal plug connector • Connector is placed at the end of coaxial cables in order to link wiring to a piece of electronic devices like camera or DVR • After the Conductor is inserted, it is locked via screw, causing pins in the socket to be connected to output interface • BNC connector is used for RF signal connections, for analog and Serial Digital Interface video signals. • BNC connector has excellent cable protection and retention. • Easy to install. • Suitable with RG6/RG59 cables

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
WBOX BNC Connector INR   0 INR  0
-NaN%

WBOX BNC Connector

WBOX Model : WBCBNCCOMPTP. These BNC compression connectors have gold plated center contacts for optimum signal transmission. Use these connectors with bulk coaxial cable and produce a high quality coaxial cable assembly or repair damaged cables. BNC CONNECTOR M COMP. RG59/62, W Box Technologies.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Algatech Drop Bolt Lock INR   0 INR  0
-NaN%

Algatech Drop Bolt Lock

Algatech Drop Bolt Lock Algatech Drop Bolt Lock Fail Safe. Locked When Energized, with magnetic induction. Door Status Signal NC Output. Algatech Drop Bolt Lock Status LED Indicator. Time Delay Feature – 0/3/6/9 seconds Single Voltage – 12Vdc.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Cisco SG300-28 28-Port Gigabit Managed Switch INR   0 INR  0
-NaN%

Cisco SG300-28 28-Port Gigabit Managed Switch

Rack-Mount 23 in. (58.4 cm) EIA: Included Jumbo Frame Support: 10 KB Routing Protocol: Static IPv4 routing Minimum Storage Temperature: -4 F Depth: 10.1 inches MTBF: 179,141 hour(s) Cables Included: 1x Serial Cable Capacity: 4K Active VLANs Height: 1.7 inches Maximum Operating Temperature: 104 F MAC Address Table Size: 16k entries Localization: North America Width: 17.3 inches Enclosure Type: Desktop, rack-mountable - 1U Maxiumum Storage Temperature: 158 F Ports: 26 x 10/100/1000 + 2 x combo Gigabit SFP Device Type: Switch - 28 ports - L3 - managed Humidity Operating Range: 10-90% (non-condensing) Weight: n/a Minimum Operating Temperature: 32 F Interfaces: 28 x 10Base-T/100Base-TX/1000Base-T - RJ-45; 1 x console - 9 pin D-Sub (DB-9) - management; 2 x SFP (mini-GBIC) Humidity Storage Range: 10-90% (non-condensing) Flash Memory: 16 MB Voltage Required: AC 120/230 V ( 50/60 Hz ) Performance: Switching capacity: 56 Gbps; Forwarding performance (64-byte packet size): 41.67 Mpps Power Device: Power supply - internal Power Over Ethernet (PoE): n/a Status Indicators: Link activity, port transmission speed, system Ram: 128 MB Authentication Method: Secure Shell (SSH), RADIUS, TACACS+

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Cisco SG350-28P 28-Port Gigabit PoE Managed Switch INR   0 INR  0
-NaN%

Cisco SG350-28P 28-Port Gigabit PoE Managed Switch

Depth: 10.1 inches MTBF: 179,141 hour(s) Cables Included: 1x Serial Cable Capacity: 4K Active VLANs Height: 1.7 inches Maximum Operating Temperature: 104 F MAC Address Table Size: 16k entries Width: 17.3 inches Enclosure Type: Desktop, rack-mountable - 1U Maxiumum Storage Temperature: 158 F Ports: 26 x 10/100/1000 + 2 x combo Gigabit SFP Device Type: Switch - 28 ports - L3 - managed Humidity Operating Range: 10-90% (non-condensing) Weight: 4K.G. Minimum Operating Temperature: 32 F Interfaces: 28 x 10Base-T/100Base-TX/1000Base-T - RJ-45; 1 x console - 9 pin D-Sub (DB-9) - management; 2 x SFP (mini-GBIC) Humidity Storage Range: 10-90% (non-condensing) Flash Memory: 16 MB Voltage Required: AC 120/230 V ( 50/60 Hz ) Performance: Switching capacity: 56 Gbps; Forwarding performance (64-byte packet size): 41.67 Mpps Power Device: Power supply - internal Power Over Ethernet (PoE): PoE 180W Status Indicators: Link activity, port transmission speed, system Ram: 256 MB Authentication Method: Secure Shell (SSH), RADIUS, TACACS+

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
AC750 Wireless Dual Band Router (Archer C20) INR   0 INR  0
-NaN%

AC750 Wireless Dual Band Router (Archer C20)

upports 802.11ac standard - the next generation of Wi-Fi Simultaneous 2.4GHz 300Mbps and 5GHz 433Mbps connections for 733Mbps of total available bandwidth 3 external antennas provide stable omni directional signal and superior wireless coverage

INR 0 INR 0

Availability:True

Pay mode:COD only

view details